Item | Content | Criterion |
Charge Protection |
Over charge detection voltage | 4.25±0.025V |
Over charge detection delay time | 200ms.TYPE |
|
Over charge release voltage | 4.145±0.050V | |
Maximum charge current | 30A |
|
Discharge Protection |
Over discharge detection voltage | 2.90±0.08V |
Over discharge detection delay time | 40ms.TYPE |
|
Over discharge release voltage | 3.00±0.08V | |
Current Protection |
Maximum continuous current | |
Over current protection current | ||
Detection delay time | 10ms.TYPE | |
Release condition | Cut load |
|
Short protection |
||
Detection condition | Exterior circuit short |
|
Detection delay time | 300us.TYPE | |
Release condition | Cut short circuit |
|
Temperature protection |
Over temperature protection | 80.5℃ |
Over temperature protection recover | 60±5℃ |
|
Over temperature protection delay time | 8±2S |
|
Balance | Balance start Voltage | 4.18V±20mV |
Balance current | 60mA.Max | |
Balance mode | ||
Interior resistance | Main loop electrify resistance | Vcu=4.2V Rss≤60mΩ |
Working condition |
Working temperature range | -30~85℃ |
Relative humidity | 5%~95% | |
Storage condition | Storage temperature | -40~95℃ |
Relative humidity | ≤75% | |
Static current comsumption | 100uA.TYPE |
|
Dimension |